Protec M+M+AR Gypsum Panels are designed for interior high-traffic areas where abrasion resistance, indentation resistance, and mold/water resistance are primary considerations. These panels are comprised of a proprietary high-density Type X gypsum core enhanced with the “Protec” mold/moisture treatment.
Protec M+M+AR Type X Gypsum Panels are designed for interior high traffic areas where abrasion, indentation resistance and mold/water resistance are primary considerations.
Protec M+M+AR Gypsum Panels are comprised of a proprietary high density. Type X gypsum core enhanced with "Protec" mold/moisture treatment. In addition, the 100% recycled blue face layer and the gold back paper are also treated with the same "Protec" inhibitor.
The face paper is formed along each edge, wrapped around and sealed to the paper on the back side. This produces a strong yet flexible panel in convenient width and length to meet most commercial/residential construction requirements for wall and ceiling substrates.
Protec M+M+AR Gypsum board is manufactured to meet or exceed the requirements of: ASTM C1396 Section 7, and CAN/CSA A82.27, Gypsum Board.
Installation according to CAN/CSA A82.31, Gypsum Board Application, and Installation Standards, ASTM C840, and specific UL/ULC requirements.
5/8" (16 mm) Protec M+M+AR Type X is UL and ULC classified.
Fire resistance tests in accordance with ASTM E119 and CAN/ULC-S102.
Non-combustible core when tested in accordance to ASTM E136 or CAN/ULC S114.
Mold Resistance: ASTM D3273 scored 10, and per ASTM G21 scored 0.
Water Absorption: ASTM C473 scored <5%
Mold Resistance: ASTM D3273 scored 10, and per ASTM G21 scored 0.
Water Absorption: ASTM C473 scored <5%
Surface Burning Characteristics: Flame Spread Rating of 15, Smoke Developed 0 per ASTM E84 or CAN/ULC-S102.
Thickness: 5/8" (15.9 mm)
Width: 48" (1220 mm)
Lengths: *8' (2440 mm) to 12' (3660 mm)
Edges: Tapered
Packaging: Two pieces per bundle, face-to-face and end taped.
*Special lengths may be available, consult nearest Cabot Gypsum sales office.
Protec M+M+AR Type X should be installed according to ASTM E840. For partitions requiring a fire rating fastener spacing, board orientation and other details must be according to the applicable published details within the UL/ULC directories.
Protec M+M+AR Gypsum Board is designed to accept most types of paints, texture and wall covering materials. The surface should be primed and sealed with a full bodied quality latex primer before applying a decorative material. This will equalize the suction variation between the joint compounds and the paper surface. If glossy paints are used in areas such as kitchens or bathrooms, a thin skim coat of compound over the entire surface is recommended to reduce highlighting or joint photographing. This method is also recommended in areas of severe side lighting of either natural or artificial light sources. Joint treatment must be thoroughly dry before proceeding with primer-sealer application and final decoration.